TM 5-2350-378-23&P
0027
INSTALLATION
WARNING
Ensure that vehicle power is off and battery disconnected. Remove all jewelry, such as rings,
dog tags, bracelets, etc. If jewelry or disconnected battery ground cable contacts battery
positive terminal, a direct short will result, causing instant heating of tools, tool damage,
battery damage, or battery explosion. Failure to comply may result in severe injury or death.
1.
Install disconnect bracket (Figure 2, Item 17) on bulkhead with two flat washers (Figure 2, Item 7) and two new
machine bolts (Figure 2, Item 6).
2.
Install HDC circuit breaker (Figure 2, Item 11) with two screws (Figure 2, Item 12), two new lockwashers
(Figure 2, Item 10), and two nuts (Figure 2, Item 9) to HDC disconnect bracket (Figure 2, Item 17).
3.
Connect circuit 1070 (Figure 2, Item 5) and circuit 10 (Figure 2, Item 8) connectors to HDC circuit breaker
(Figure 2, Item 11).
4.
Connect wiring harness connector W3J1 (Figure 2, Item 4) to disconnect bracket (Figure 2, Item 17) with
nutplate (Figure 2, Item 3) and four screws (Figure 2, Item 13).
5.
Connect wiring harness connector W2J1 (Figure 2, Item 19) to disconnect bracket (Figure 2, Item 17) with
nutplate (Figure 2, Item 2) and four screws (Figure 2, Item 15).
6.
Connect wiring harness connector W1J1 (Figure 2, Item 18) to disconnect bracket (Figure 2, Item 17) with
nutplate (Figure 2, Item 1) and four screws (Figure 2, Item 16).
7.
Install dust caps (Figure 2, Item 14) on wiring harness connectors W3J1 (Figure 2, Item 4), W2J1
(Figure 2, Item 19), and W1J1 (Figure 2, Item 18).
8
9 10
11
5
3
6
2
12
4
7
1
19
13
18
17
15
14
14
16
14
M0005HDC
Figure 2. Hydraulic Diagnostic Center (HDC) Disconnect Bracket Installation.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00003)