TM 5-2350-378-23&P
0028
INSTALLATION
1.
Install HDC circuit breaker (Figure 2, Item 7) on HDC disconnect bracket (Figure 2, Item 9) with two screws
(Figure 2, Item 8), new lockwashers (Figure 2, Item 6), and nuts (Figure 2, Item 5).
2.
Connect circuit 10 and circuit 1070 connectors (Figure 2, Items 3 and 4) to HDC circuit breaker
(Figure 2, Item 7).
3.
Install disconnect bracket (Figure 2, Item 9) on bulkhead with two washers (Figure 2, Item 1) and new machine
bolts (Figure 2, Item 2).
4
5
6
7
3
8
2
1
9
M0009HDC
END OF TASK
FOLLOW-ON MAINTENANCE
Connect negative battery cables (TM 5-2350-262-20).
END OF TASK
END OF WORK PACKAGE
03/15/2011Rel(1.8)root(maintwp)wpno(M00004)