EJECTOR CREEPS - Continued
Figure 9. Ejector Relief Valve Adjustment.

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
.
TM 5-2350-378-23&P
0010
EJECTOR CREEPS - Continued
CONDITION/INDICATION
Is transducer T-2 hydraulic pressure between 1,950-2,050 psi (13,445-14,135 kPa)?
DECISION
YES - Go to Step (8).
NO - Go to Step (7).
STEP
7.
Perform ejector relief valve adjustment.
a.
Disable ejector by manually closing the ejector inhibit ball valve V23 (Figure 7, Item 1) on DCV bank.
1
T00810HDC
Figure 7. Directional Control Valve (DCV) Bank.
b.
Using LINE UP or LINE DOWN button (Figure 8, Item 3), select V1 on HDC display (Figure 8, Item 2).
c.
Close V1 on HDC display (Figure 8, Item 2) by selecting CHANGE POSITION button
(Figure 8, Item 4) on HDC control box.
d.
Have assistant start engine and hold EJECTOR CONTROL lever in FORWARD position.
e.
Read transducer T-2 hydraulic pressure on HDC display (Figure 8, Item 1).
0010-8